  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8. Recommendation R.116 (R.11m)
  9.  
  10.       MAINTENANCE TESTS TO BE CARRIED OUT ON INTERNATIONAL
  11.                            TDM SYSTEMS
  12.  
  13.  
  14.        The CCITT,
  15.  
  16. considering
  17.  
  18.        a)   the savings to be made by reducing interruption time  on  TDM
  19. links;
  20.  
  21.        b)   the importance of being able  to  determine  responsibilities
  22. between the several parties who, of necessity are involved in maintenance 
  23. questions for the networks;
  24.  
  25.        c)   the advantages of standardization regarding maintenance;
  26.  
  27.        d)   maintenance loops are standardized in Recommendation R.115,
  28.  
  29. unanimously declares the following:
  30.  
  31.        that when the quality of the TDM-link has deteriorated beyond  the  alarm
  32. limit or if the local muldex gives an alarm, supplementary measurement should be 
  33. performed. The following test and supervision methods can be used.
  34.  
  35. 1.     Testing and supervision of TDM systems
  36.  
  37. 1.1    Bit error rate
  38.  
  39.        The synchronization bits are supervised and an error rate alarm is issued 
  40. when the error rate exceeds a preset limit, 10-3, 10-4 or 10-5.
  41.  
  42. 1.2    Bit error counter
  43.  
  44.        All synchronization bit errors shall be registered in a cyclic counter and 
  45. it shall be possible to read the value of this counter by command.
  46.  
  47. 1.3    Routine supervision
  48.  
  49.        The operation  of  the  TDM  equipment  and  maintenance  channel  should
  50. continuously be supervised by a repetitive test signal. An alarm is issued when a 
  51. correct acknowledgement is not received for a specified number of test signals.  The 
  52. alarm is reset automatically when the fault situation ceases.
  53.  
  54. 1.4    Alarm reset
  55.  
  56.        It shall be possible to reset all alarms from the local side. The command 
  57. shall also be able to reset the error rate value.
  58.  
  59. 1.5    System alarms
  60.  
  61.        Failures that affect operation of the whole or a major part  of  the  TDM
  62. equipment are classified as one category. The supervised functions are:
  63.  
  64.        -    Carrier:         Loss of carrier is detected by the data modem
  65.                             through CCITT circuit 109 or  the  corresponding
  66.                             circuit.
  67.  
  68.  
  69.  
  70.  
  71.  
  72.  
  73.  
  74.  
  75.  
  76.  
  77.  
  78.  
  79.        -    Synchronization: Loss of synchronization is detected by the TDM
  80.                             multiplexer in  accordance  with  the  respective
  81.                             CCITT Recommendation.
  82.  
  83.        -    Multiplexing     Failure of the TDM central logic is  detected  by
  84.          logic:             internal   supervision   facilties   within    the
  85.                   multiplexer.
  86.  
  87.        -    Power:           Failure of the power supply is detected  when  the
  88.                               telegraph   power   supply   exceeds    tolerance
  89.                              limits.
  90.  
  91. 1.6    Changing of active side
  92.  
  93.        When the TDM equipment is duplicated the active side can be  changed  by
  94. command or manually.
  95.  
  96.        When the remote or local side  is  changed  automatically  or  manually,
  97. information about what side is executive must be sent when the change has  been
  98. executed.
  99.  
  100. 1.7    Looptest on standby side
  101.  
  102.        When the TDM equipment is duplicated the standby modem can be tested by the 
  103. setting of loop b by command. The test result is sent over the active maintenance 
  104. channel.
  105.  
  106. 1.8    Automatic restart
  107.  
  108.        When the remote TDM is automatically restarted, information shall be sent 
  109. informing about the restart and alarm status.
  110.  
  111. 1.9    Acknowledgement
  112.  
  113.        The acknowledgement consists of one character and should have the following 
  114. values:
  115.  
  116.        5 - Acknowledgement;
  117.  
  118.        0 - Not acknowledgement.
  119.  
  120. 2.     Format of the messages
  121.  
  122.        The messages which will be sent over the 50 baud  maintenance  channel
  123. shall have the following structure:
  124.  
  125.        C1C2M1M2....Mn;
  126.  
  127.        C1C2: Message category (two characters);
  128.  
  129.        M1-Mn: Information (number of characters unlimited).
  130.  
  131.        After the reception of a message at the receiving end, the receiving end 
  132. shall send one character to the originating end as an acknowledgement of  the
  133. reception.
  134.  
  135. 2.1    Message categories
  136.  
  137.        The purpose of the message categories (called MC) is to give a  direct
  138. command or to inform the control equipment in an exchange, a maintenance centre 
  139. or a TDM about what type of information the following message contains.
  140.  
  141.  
  142.  
  143.  
  144.  
  145.  
  146.  
  147.        The MC consist of two characters, and each character is a decimal number 
  148. from 0 to 9. The numbers are coded according to alternative A (CSC) in R.115.
  149.  
  150. 2.2    Information
  151.  
  152.        The information characters are a part of an order to  the  remote  TDM
  153. equipment or information from the remote TDM-equipment, depending on the Message 
  154. Category Signal.
  155.  
  156.        The number of information characters in a message is not limited.
  157.  
  158.        The characters are decimal numbers from 0 to  9,  coded  according  to
  159. alternative A(CSC) in R.115.
  160.  
  161. 3.     Maintenance messages
  162.  
  163.        Using the format described in  2 the maintenance messages shall  have  a
  164. message category and information as given in the table below:
  165.  
  166.  
  167.                                     TABLE 1
  168.                                         
  169.                               Maintenance messages
  170.  
  171.  
  172. ────────────────────────────────────────────────────────────────────────── 
  173.  
  174.  
  175.  
  176.  
  177.  
  178.  
  179.