MTP LEVEL 3
TEST NUMBER: 1.1 PAGE: 1 of 1
REFERENCE:Q.704 S 3 Fig. 7, Fig. 36, Fig. 37, Fig. 38
TITLE:Signalling link management
SUBTITLE:First signalling link activation
PURPOSE:To put into service a signalling linkset with 1 signalling
link
PRE-TEST CONDITIONS:Signalling links deactivated
CONFIGURATION:A TYPE OF TEST:VAT, CPT TYPE OF SP:
ALL
MESSAGE SEQUENCE:
SPA SPB
Link Link
Fascicle VI.9 - Rec. Q.782 PAGE251
1 - 1 :Activate
1 - 1 :Activate
<------------- 1 - 1SLTM
---
1 - 1 SLTA -------------
---->
1 - 1 SLTM -------------
---->
<------------- 1 - 1SLTA
---
:Start traffic
PAGE256 Fascicle VI.9 - Rec. Q.782
1 - 1 TRAFFIC --------------
--->
<------------- 1 - 1TRAFFIC
---
:Wait
:Stop traffic
TEST DESCRIPTION
1. Check that the signalling link becomes available.
2. Check the reception and sending of variable length messages on the
activated linkset from/to the SP at the other end of this linkset (and,
in case of VAT, from/to other SP crossing the SP at the other end of
this linkset).
3. Check that, after the alignment, the level 2 does not send any message
received before or during the deactivation.
4. Check that all messages are correctly received (no loss of messages, no
duplication and no missequencing).
5. Stop traffic.
Fascicle VI.9 - Rec. Q.782 PAGE251
6. Repeat the test with different SLC values.
PAGE256 Fascicle VI.9 - Rec. Q.782
MTP LEVEL 3
TEST NUMBER: 1.2 PAGE: 1 of 1
REFERENCE:Q.704 S 3 Fig. 7, Fig. 36, Fig. 37, Fig. 38
TITLE:Signalling link management
SUBTITLE:Signalling linkset deactivation
PURPOSE:To remove from service a signalling linkset with 1
signalling link
PRE-TEST CONDITIONS:One signalling link (1-1) activated
CONFIGURATION:A TYPE OF TEST:VAT, CPT TYPE OF SP:ALL
MESSAGE SEQUENCE:
SPA SP B
Link Link
1 - 1Deactivate
Fascicle VI.9 - Rec. Q.782 PAGE251
TEST DESCRIPTION
1. Check that the signalling linkset becomes unavailable.
MTP LEVEL 3
TEST NUMBER: 1.3 PAGE: 1 of 1
REFERENCE:Q.704 S 3, 12.2.4.1 Fig. 7, Fig. 36, Fig. 37, Fig. 38
TITLE:Signalling link management
SUBTITLE:Signalling linkset activation
PURPOSE:To put into service a signalling linkset with 4 signalling
links
PRE-TEST CONDITIONS:Signalling links deactivated
PAGE256 Fascicle VI.9 - Rec. Q.782
CONFIGURATION:A TYPE OF TEST:VAT, CPT TYPE OF SP:ALL
MESSAGE SEQUENCE:
SPA SP B
Link Link
1 - 1 :Activate 1 - 1 :Activate
1 - 2 :Activat
1 - 2 :Activate
1 - 3
Fascicle VI.9 - Rec. Q.782 PAGE251
:Activate
1 - 3 :Activate
1 - 4 :Activate
1 - 4 :Activate
:Start
traffic
1 - 1 TRAFFIC ------------
----->
<------------ 1 - 1
----
PAGE256 Fascicle VI.9 - Rec. Q.782
TRAFFIC
1 - 2 TRAFFIC ------------
----->
<------------ 1 - 2 TRAFFIC
----
1 - 3 TRAFFIC ------------
----->
<------------ 1 - 3 TRAFFIC
----
1 - 4 TRAFFIC ------------
----->
<------------ 1 - 4 TRAFFIC
----
:Wait
Fascicle VI.9 - Rec. Q.782 PAGE251
:Stop traffic
Note - This test describes the activation of a linkset. The signalling link
activation order is given simultaneously to all signalling links of the signalling
linkset (Q.704 S 12.2.4.1). However, depending on in which order the links are
getting aligned, changeback procedures will be performed. This test does not
describe the transitory states (changeback procedure is checked in other tests).
TEST DESCRIPTION
1. Check that the signalling links become available and start traffic between A
and B (and A and C in VAT).
2. Check the reception and sending of variable length messages on the activated
linkset from/to the SP at the other end of this linkset (and, in case of
VAT, from/to other SP crossing the SP at the other end of this linkset).
3. Check that, after the alignment, the level 2 does not send any message
received before or during the deactivation.
4. Check that all messages are correctly received (no loss of messages, no
duplication and no missequencing).
5. Stop traffic.
MTP LEVEL 3
TEST NUMBER: 2.1 PAGE: 1 of 1
REFERENCE:Q.704 S 3 Fig. 24 S 2.4
TITLE:Signalling message handling
SUBTITLE:Message received with an invalid SSF (discrimination
function)
PAGE256 Fascicle VI.9 - Rec. Q.782
PURPOSE:To check the response to a message with an invalid SSF
PRE-TEST CONDITIONS:Signalling linkset activated
CONFIGURATION:A TYPE OF TEST:VAT TYPE OF SP:ALL
MESSAGE SEQUENCE:
SPA SP B
Link Link
<---------------- :Invalid SLTM
1 - 1 :(invalid SSF)
TEST DESCRIPTION
1. Send an SLTM with an erroneous SSF.
2. Check that no response is received.
Fascicle VI.9 - Rec. Q.782 PAGE251
PAGE256 Fascicle VI.9 - Rec. Q.782
MTP LEVEL 3
TEST NUMBER: 2.2 PAGE: 1 of 1
REFERENCE:Q.704 S 2 Fig. 24, Fig. 26
TITLE:Signalling message handling
SUBTITLE:Message received with an invalid DPC
PURPOSE:To check the response to a message with an invalid DPC
PRE-TEST CONDITIONS:Signalling linkset activated
CONFIGURATION:A TYPE OF TEST:VAT TYPE OF SP:ALL
MESSAGE SEQUENCE:
SPA SP B
Link Link
<----------------
Fascicle VI.9 - Rec. Q.782 PAGE251
1 - 1 :Invalid ECO
:(erronenous DPC)
1 - 1TFP -----------------> (only if the tested point A has an
STP function)
TEST DESCRIPTION
1. Send a ECO message with an erroneous DPC.
2. Check that no response is received if the tested point has not STP
function. If the tested point has the STP function, check that a TFP is
received.
PAGE256 Fascicle VI.9 - Rec. Q.782
MTP LEVEL 3
TEST NUMBER: 2.3 PAGE: 1 of 1
REFERENCE:Q.704 S 2.4 Fig. 24, Fig. 25
TITLE:Signalling message handling
SUBTITLE:Message received with an erroneous SI (distribution
function)
PURPOSE:To check the response to a message received with an erroneous
SI
PRE-TEST CONDITIONS:Signalling linkset activated
CONFIGURATION:A TYPE OF TEST:VAT TYPE OF SP:ALL
MESSAGE SEQUENCE:
SPA SP B
Link Link
<------------------
Fascicle VI.9 - Rec. Q.782 PAGE251
1 - 1 :invalid SLTM
:(invalid SI)
TEST DESCRIPTION
1. Send an SLTM message with an invalid SI.
2. Check that no response is received.
PAGE256 Fascicle VI.9 - Rec. Q.782