All drawings appearing in this Recommendation have been done in Autocad.
Recommendation Q.541
DIGITAL EXCHANGE DESIGN OBJECTIVES - GENERAL
1 General
This Recommendation applies to digital local, combined, transit and
international exchanges for telephony in Integrated Digital Networks (IDN) and
mixed (analogue/digital) networks, and also to local, combined, transit and
international exchanges in an Integrated Services Digital Network (ISDN). The
field of application of this Recommendation is more fully defined in
Recommendation Q.500. Some objectives only apply to a certain type (or types) of
exchange. Where this occurs, the application is defined in the text. Where no
such qualification is made, the objective applies to all exchange applications.
2 General design objectives
The exchange and/or any associated operations and maintenance
systems/centers shall have the capabilities needed to allow the exchange to be
operated and administered efficiently while providing service in accordance with
an Administration's performance requirements.
2.1 Exchange modifications and growth
The exchange should be capable of having hardware and/or software added or
changes made without causing a significant impact on service (see SS 4.4, 4.10.2
- Planned outages).
2.2 Service provisioning and records
There should be efficient means of establishing service, testing,
discontinuing service and maintaining accurate records for:
- subscriber lines and services,
- interexchange circuits.
2.3 Translations and routing information
There should be efficient means of establishing, testing and changing call
processing information, such as translation and routing information.
2.4 Resource utilization
There should be efficient means of measuring performance and traffic flows
and to arrange equipment configurations as required to insure efficient use of
system resources and to provide a good grade of service to all subscribers (e.g.,
load balancing).
2.5 Physical design objectives
The exchange shall have a good physical design that provides:
- adequate space for maintenance activities,
- conformance with environmental requirements,
- uniform equipment identification (conforming with the Administration's
requirements),
- a limited number of uniform power up/down procedures for all component
parts of the exchange.
3 Integrated Digital Network design objectives
3.1 Exchange timing distribution
The timing distribution system of an exchange will be derived from a
highly reliable exchange clock system. The distribution of timing within the
exchange must be designed so that the exchange will maintain synchronism on 64
kbit/s channel timeslots in a connection through the exchange.
3.2 Network synchronization
Within a synchronized IDN/ISDN, different methods of providing timing
between exchanges may be used. An exchange should be able to be synchronized:
a) by an incoming digital signal at an interface A (or B, if provided) as
defined in Recommendation Q.511; this applies only to signals derived
from a Primary Reference Source, as defined in Recommendation G.811;
b) directly by a Primary Reference Source, using an interface complying
with Recommendation G.811;
c) optionally, by an analogue signal at one of the frequencies listed in
Recommendation G.811.
Plesiochronous operation should also be possible.
The clock of the local, combined or transit exchange shall be responsible
for maintaining the synchronization in the part of the network associated with
that exchange.
The timing performance of the clocks in local, combined or transit
exchanges should comply with Recommendation G.811. The timing performance of
clocks at subscriber premises, at digital PABXs, in digital concentrators, at
FascicleVI.5 - Rec. Q.541 PAGE1
muldexes, etc., require further study.
Synchronized national networks may be provided with exchange clocks not
having the frequency accuracy required for international interworking. However,
when these synchronized networks within national boundaries are required to
interwork internationally as part of the international IDN/ISDN, it will be
necessary to provide means to operate these national networks to the
internationally recommended value of frequency accuracy in Recommendation G.811.
3.3 Slip
The design objective controlled slip rate within a synchronized region
(see Note) controlled by the exchange should be zero provided that input jitter
and wander remain within the limits given in Recommendation G.823 and G.824.
The design objective controlled slip rate at a digital exchange in
plesiochronous operation (or operating to another synchronized region) shall be
not more than one slip in 70 days in any 64 kbit/s channel, provided that input
jitter and wander remain within the limits given in Recommendations G.823 and
G.824.
The operational performance requirements for the rate of octet slips on an
international connection or corresponding bearer channel are covered in
Recommendation G.822.
The occurrence of a controlled slip should not cause loss of frame
alignment.
Note - A synchronized region is defined as a geographic entity normally
synchronized to a single source and operating plesiochronously with other
synchronized regions. It may be a continent, country, part of a country or
countries.
3.4 Relative Time Interval Error (TIE) at the exchange output
Relative Time Interval Error (TIE) at the exchange output is defined as
the difference in time delay of a given timing signal when compared to a
reference timing signal for a given measurement period (see
Recommendation G.811).
3.4.1 Interface V1
Relative Time Interval Error (TIE) at the exchange output at the interface
to the basic access digital section requires further study.
3.4.2 Interfaces A, B, V2, V3 and V4
The relative TIE at the output of the digital interfaces A, B, V2, V3 and
V4 over the period S seconds should not exceed the following limits:
1) (100 S) ns + 1/8 UI for S < 10.
2) 1000 ns for S 10 (see Figure 4/Q.541).
Figure 1/Q.541 - CCITT 72171
In the case of synchronous operation the limits are specified on the
assumption of an ideal incoming synchronizing signal (no jitter, no wander and no
frequency deviation) on the line delivering the timing information. In the case
of asynchronous operation the limits are specified assuming no frequency
deviation of the exchange clock, (this is equivalent to taking the output of the
exchange clock as the reference timing signal for the relative TIE measurements).
It is recognized that the approach of using relative TIE to specify the
performance of an exchange in the case of synchronous operation in some
implementations (e.g., when mutual synchronization methods are used) requires
further study.
Any internal operation or rearrangement within the synchronization and
timing unit or any other cause should not result in a phase discontinuity greater
than 1/8 of a Unit Interval (UI) on the outgoing digital signal from the
exchange.
The limits given in Figure 4/Q.541 may be exceeded in cases of infrequent
internal testing or rearrangement operations within the exchange. In such cases,
the following conditions should be met:
The Relative Time Interval Error (TIE) over any period up to 211 unit
intervals should not exceed 1/8 of a UI. For periods greater than 211 UI, the
phase variation for each interval of 211 UI should not exceed 1/8 UI up to a
maximum total Relative TIE defined in Recommendation G.811 for long time periods.
3.5 Synchronization requirements when interworking with a digital satellite
system
On a provisional basis the following should apply:
The transfer from the timing of the terrestrial digital network to the
PAGE2 Fascicle VI.5 - Rec. Q.541
timing of the satellite system, if required (plesiochronous operation), will not
be performed by the digital exchange. The earth station will be equipped with
buffer memories of suitable size to compensate for the time delay variations due
to shifts of the satellite from its ideal position (and due to any other
phenomena with similar effects) and to meet the slip performance requirements
established in CCITT Recommendation G.822.
4 Availability design objectives
4.1 General
Availability is one aspect of the overall quality of service of an
exchange.
Availability objectives are important factors to be considered in the
design of a switching system and may also be used by administrations to judge the
performance of a system design and to compare the performance of different system
designs.
Availability may be determined by collecting and evaluating data from
exchanges in operation in accordance with draft Recommendation E.450. Data
collection may be facilitated by the use of the Telecommunications Management
Network (TMN).
Availability may be expressed as the ratio of the accumulated time during
which the exchange (or part of it) is capable of proper operation to a time
period of statistically significant duration called the mission time.
Availability (A) = eq \f(accumulated up-time,mission time) = eq \f(accumulated
up-time,accumulated up-time + accumulated down-time)
Sometimes it is more convenient to use the term unavailability (instead of
availability) which is defined as:
Unavailability (U) = 1 - A.
The terms used in this section, when they already exist, are in accordance
with CCITT Recommendation G.106.
4.2 Causes of unavailability
This Recommendation deals with availability as observed from the exchange
termination point of view. Both planned and unplanned outages need to be
considered, and both types need to be minimized. Unplanned outages reflect on the
inherent reliability of the exchange and are therefore considered separately from
planned outages in this Recommendation.
Unplanned unavailability counts all failures that cause unavailability.
Thus hardware failure, software malfunctions and unintentional outages resulting
from craftperson activity are to be counted.
4.3 Intrinsic and operational unavailability
Intrinsic unavailability is the unavailability of an exchange (or part of
it) due to exchange (or unit) failure itself, excluding the logistic delay time
(e.g. travel times, unavailability of spare units, etc.) and planned outages.
FascicleVI.5 - Rec. Q.541 PAGE1
Operational unavailability is the unavailability of an exchange (or part
of it) due to exchange (or unit) failure itself, including the logistic delay
time (e.g. travel times, unavailability of spare units, etc.).
4.4 Planned outages
Planned outages are those intentionally induced to facilitate exchange
growth or hardware and/or software modifications. The impact of these activities
on service depends on their duration, the time of day they are introduced and on
the particular system design.
4.5 Total and partial unavailability
Exchange unavailability may be either total or partial. Total
unavailability affects all terminations, and consequently, all traffic that is
offered during the outage is equally affected. A partial outage has an effect
only on some terminations.
From the point of view of one termination on an exchange (e.g. a
subscriber line termination), the numerical value of mean accumulated downtime
(and hence the unavailability) for a specified period of time should not depend
on the exchange size or its traffic handling capacity. Similarly, from the point
of view of a group of terminations of size n, the mean accumulated downtime for a
specified period of time, in case they are simultaneously unavailable, should not
depend on exchange size. However, for two groups of terminals of differing size n
and m such that n is greater than m (n > m), the mean accumulated downtime (and
hence the unavailability) for n will be less than the mean accumulated downtime
(MADT) or the unavailability for m.
Thus:
MADT(n) < MADT(m) where n > m
and
U(n) < U(m)
The lower limit of m is one termination, and it can be specified as having
a mean value of T minutes per year.
4.6 Statistical basis
Any estimation of unavailability is of necessity a statistical quantity,
because outages are presumed to occur randomly and they are of random duration.
Therefore, availability measurements are significant when made over a
statistically significant number of exchanges. It follows then, that a single
exchange may exceed the unavailability objectives. Further, to be statistically
significant the mission time must be adequate in order to have sufficient
collected data. The accuracy of the result is dependent on the amount of
collected data.
4.7 Relevant failure events
Different types of failure events may occur in an exchange. In order to
evaluate the unavailability of an exchange (or part of it) only those events
having an adverse effect on the exchange's ability to process calls as required
should be taken into account. A failure event which is short in duration and
results only in call delay rather than in a call denial can be disregarded.
4.8 Availability independence
The design objectives for the unavailability of a single termination or
any group of terminations of size n are independent of exchange size or internal
structure.
4.9 Intrinsic downtime and unavailability objectives
The recommended measure for use in determining intrinsic unavailability is
mean accumulated intrinsic down time (MAIDT) for individual or groups of
terminations, for a given mission time, typically one year.
PAGE2 Fascicle VI.5 - Rec. Q.541
For one termination:
MAIDT(1) ú 30 minutes per year.
For an exchange termination group of size n:
MAIDT(n) < MAIDT(m) where n > m.
This reflects the consequences (e.g. traffic congestion, social annoyance,
etc.), of the simultaneous outage of a large number of terminations.
The above expression is a statement of principle and means that units
serving larger group sizes shall have lower MAIDT.
4.10 Operational unavailability objectives
4.10.1 Logistic delay time
Due to differing national conditions, logistic delay times may vary from
country to country and therefore may not be subject to international
Recommendation.
Nevertheless, for design guidance, an indication of the Administration's
logistic delays is considered desirable to establish overall operational
performance objectives. It is left for the operating Administration to determine
how it should be accounted for in the determination of operational
unavailability.
4.10.2 Planned outages
Planned outages are to be minimized to the greatest extent practicable.
They should be scheduled so as to have least impact on service practicable.
4.11 Initial exchange availability performance
A system rarely meets all long-term design objectives when first placed
into service. The objectives contained in this Recommendation may therefore not
be fulfilled for a limited period of time after the newly designed switched
system has been put into service; this period of time should be minimized to the
greatest extent practicable.
5 Hardware reliability design objectives
A bound on the rate of hardware failures is recommended. It includes all
types of hardware failures and the failures counted are independent of whether or
not there is a resulting service degradation.
An acceptable hardware failure rate for an exchange is a function of the
exchange size and the types of terminations.
The following formula can be used to verify that the maximum failure rate
does not exceed the Administration's requirements:
eq Fmax = C0 + \i\su(i=1,n,) CiTi
where:
Fmax the maximum acceptable number of hardware failures per unit of
time;
Ti the number of terminations of type i;
n the number of distinct types of terminations;
C0 to be determined taking into account all failures which are independent
of exchange size;
Ci coefficients for terminations of type i, reflecting the number of
failures associated with individual terminations of that type.
Different hardware used with different types of terminations may result
in different values for Ci.
FascicleVI.5 - Rec. Q.541 PAGE1