home *** CD-ROM | disk | FTP | other *** search
/ Internet Standards / CD2.mdf / ccitt / 1992 / q / q115.asc < prev    next >
Text File  |  1991-12-30  |  16KB  |  363 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. Updated Recommendation Q.115
  8.  
  9.  
  10.                            SECTION 3
  11.  
  12.         CONTROL OF ECHO SUPPRESSORS AND ECHO CANCELLERS
  13.               BY INTERNATIONAL SWITCHING CENTRES 
  14.  
  15. 3.1    General
  16.  
  17.        In order to achieve transmission objectives on long automatic  and  semi-
  18. automatic telephone connections, it  is  necessary  to  take  into  account  the
  19. effects of echo. A general discussion of echo considerations is given in Recommendation 
  20. Q.42 which is an extract of Recommendation G.131. The characteristics of terminal 
  21. half-echo control devices are given in Recommendations G.161 [1] and G.164  [2].
  22. The characteristics of echo cancellers are given in Recommendation G.165 [3].
  23.  
  24.        In order to achieve optimum echo control for each call, it  is  necessary
  25. to control both types of echo control devices.
  26.  
  27.        This  can  be  carried  out  at  switching  centres  only  if  sufficient
  28. information is available to coordinate an overall control action.
  29.  
  30.        Logical  means  to  obtain  pertinent  information  and   the   switching
  31. considerations governing its practicable use are detailed below. Control based on the 
  32. transfer of signals between switching centres is given particular attention. Self-contained control action such as tone disablement of echo suppressors and echo 
  33. cancellers for data transmission is not within the scope of this section.
  34.  
  35.        In the cases  to  be  discussed,  control  methods  will  be  applied  at
  36. international exchanges (CTs), but it is recognized that in some countries covering large 
  37. geographic areas it may be  appropriate  to  extend  the  control  methods  into
  38. national networks.
  39.  
  40.        The actions described in  3.5 to 3.8 about the analysis of  information
  41. and the decision to be taken in an outgoing transit  or  incoming  international
  42. exchange are summarized in the SDL flowchart of Annex A.
  43.  
  44.        Annex A does not cover the handling of echo control devices in  the  case
  45. of different bearer services and CCITT Signalling System No. 7.
  46.  
  47. 3.2    Terminology
  48.  
  49. a)     Subsequent discussion of control measures  will  refer  to  the  standard
  50. terminal half-echo suppressor specified in Recommendation G.164 [2] and the echo 
  51. cancellers specified in Recommendation G.165 [2]. The terms echo suppressor and echo 
  52. canceller will be used to denote these devices. The term echo control device will 
  53. comprise both, echo suppressors and echo cancellers.
  54.  
  55. b)      Two  means  of  introducing  echo  control  devices  are  considered  as
  56. acceptable, these are, the use of permanently associated echo control devices and the use 
  57. of echo control devices inserted from a common pool of echo control devices.
  58.  
  59. c)     With respect to control of permanently associated  echo  control  devices
  60. control actions are said to enable or disable.
  61.  
  62.  
  63.  
  64.  
  65.  
  66.  
  67.  
  68.  
  69.  
  70.  
  71.  
  72.  
  73. d)     With respect to echo control devices provided from pools, control actions 
  74. are concerned with inserting or not inserting.
  75.  
  76. e)     The signals assigned in Systems R2, No. 6 and  No.  7  (and  reserved  in
  77. System No. 4) for echo control equipment control are in most cases a means to guide 
  78. subsequent exchanges  in  taking  necessary  action  with  respect  to  possible
  79. introduction of an incoming echo control device. Thus the descriptive phrases associated 
  80. with the various signalling systems, as given below, convey comparable meaning in 
  81. the control plan.
  82.  
  83.        Systems No. 4 and R2: incoming half-echo  suppressor  (half-echo
  84.        canceller) required;
  85.  
  86.        Systems No. 6 and No. 7: outgoing half-echo  suppressor  (half-echo
  87.        canceller) included in the connection.
  88.  
  89. f)     A secondary signalling function related to echo control  device  control
  90. provides for the possibility that echo control device may not be available at
  91. an originating CT. In this case responsibility for both outgoing and incoming echo 
  92. control device may be delegated by signal.
  93.  
  94. g)     A long circuit is considered as one which, if used by itself, would require 
  95. echo control.
  96.  
  97. h)     A short circuit is considered as one which, if used by  itself,  would  not
  98. require echo control.
  99.  
  100. 3.3    Compatibility of echo control devices and signalling equipment
  101.  
  102.        a)   Arrangements should be incorporated  in  the  switching  equipment  to
  103. prevent echo suppressor and echo canceller action from disturbing simultaneous forward 
  104. and backward signalling via the speech paths.
  105.  
  106.        For this case typical arrangements are:
  107.  
  108.        i)   locating the echo control device on  the  switching  side  of  the
  109.             signalling equipment;
  110.  
  111.        ii)  inhibiting the action of echo control device located on  the  line
  112.             side   of   the   signalling   equipment   by    means    of    an
  113.             appropriate    condition    extended    from    the     signalling
  114.             equipment to the  echo  control  device  while  signalling  is  in
  115.             progress.
  116.  
  117. Note 1 - The standard half-echo suppressor (Recommendations G.161  [1]  and
  118. G.164 [2]) if located on the line side of  line  signalling  equipment  may
  119. adversely affect signalling. This difficulty is possible because with the new 
  120. standard half-echo suppressor normal operation will at  times  cause  6  dB
  121. additional loss to appear in the path to a line signalling receiver. Operating 
  122. margins are correspondingly reduced. For example, with signalling receivers
  123. for System No. 5 as specified in Recommendation Q.112, signalling reliability could 
  124. be impaired. Accordingly, adequate operating margins should be assured or the echo 
  125. suppressor should not be located on the line side of  line  signalling  receivers.
  126. With regard to inter-register signalling which requires simultaneous transmission in 
  127. both directions, similar considerations call for disabling  the  echo  suppressors
  128. while inter-register signalling is in progress in order to prevent the 6 dB loss.
  129.  
  130.  
  131.  
  132.  
  133.  
  134.  
  135.  
  136. Note 2 - Echo  cancellers  will  not  introduce  any  fixed  loss  during  in-band
  137. signalling. But they can cause a problem during the continuity check used in CCITT 
  138. Signalling    Systems    No.     6     (Recommendation     Q.271)     and     No.7
  139. (Recommendation Q.724), or with compelled signals having the same frequency(ies)  on both directions 
  140. of transmission in Signalling System No. 5                   (Recommendation Q.112) 
  141. where the received signal is processed through the existing echo  path  model  and
  142. produces an interfering signal in the return path.
  143.  
  144. Note 3 - Some echo control devices are  capable  of  internally  providing  either
  145. signalling bypass or an appropriate internal function  which  permits  transparent
  146. operation to in-band signalling or other in-band tones.
  147.  
  148. b)     Arrangements should be  incorporated  in  the  Systems  No.  6  and  No.  7
  149. equipment to prevent echo suppressor action from disturbing the procedure for making the 
  150. continuity check of the speech path. Echo suppressors and echo cancellers must  be
  151. permanently disabled, if a circuit is used for common channel signalling.
  152.  
  153. 3.4    Operation without signals
  154.  
  155.        In Signalling Systems No. 5 and R1, signals  are  not  available  for  echo
  156. control information. In System No. 4 a signal may be applied only if multilateral or 
  157. bilateral agreements authorize its use. Accordingly the recommended  control  plan
  158. relies on means other than signals in cases where it has not been found practicable to 
  159. provide signals. In the case of System No. 5, the normal field of  application  to
  160. long circuits typically indicates the presence of echo control device. In the case of 
  161. System R1, regional control procedures not requiring signals are applicable.
  162.  
  163. 3.5    Analysis of information at an outgoing international exchange
  164.  
  165.        The outgoing international exchange, hereafter designated "A", must make  a
  166. decision with respect to its echo control requirements at  the  time  an  outgoing
  167. circuit is selected. Unless echo control devices are not available, one or more of the 
  168. following items of information should influence this decision:
  169.  
  170.        i)        country code of destination and possibly some  additional  address
  171.             digits;
  172.  
  173.        ii)  information about the actual routing of the call;
  174.  
  175.        iii)      nature of outgoing international  circuit  at  A  (e.g.  satellite
  176.             circuit);
  177.  
  178.        iv)  nature of incoming national circuit at A;
  179.  
  180.        v)   signals received over the incoming national circuit at A;
  181.  
  182.        vi)       requested bearer service (see Recommendation I.231[4]).  
  183.  
  184.        With respect to iii) and iv), the characteristic of primary  interest  is
  185. propagation time. Two general categories, long  and  short,  are  the  basis  of
  186. control action. See  3.3 g) and h) above, for definition of terminology.
  187.  
  188.  
  189.  
  190.  
  191.  
  192.  
  193.  
  194.  
  195.  
  196.  
  197.  
  198.  
  199. 3.6    Decision to be taken at the outgoing international exchange
  200.  
  201.        If the factors i) to vi) in  3.5 above indicate that there is no need to 
  202. provide echo control devices on a particular connection, the  outgoing  exchange
  203. should act accordingly and  advise  subsequent  exchanges  by  signal  or  other
  204. appropriate means, of its decision.
  205.  
  206.        If  the  information  available  indicates  that  the  connection  to  be
  207. established will require echo control and if it is known that an outgoing echo control 
  208. device is not already provided in the national network, then the outgoing exchange 
  209. should provide for the outgoing echo control device. The outgoing exchange should 
  210. also, if signals are available, indicate by signal to  subsequent  exchanges  as
  211. appropriate what action it has taken.
  212.  
  213.        In the event that an outgoing exchange is unable to provide  an  outgoing
  214. echo control device when a need is known, it may call  for  cooperative  action.
  215. (Signal I-11 in System R2 is specifically assigned to make possible a cooperative 
  216. transfer of responsibility for echo control device control from an originating CT to 
  217. a transit CT. The signal outgoing half-echo suppressor not included could be used 
  218. with Systems No. 6 and No. 7, but such an application would in effect assume that 
  219. a modern exchange found sufficient reason to displace an outgoing  echo  control
  220. device from its preferred location.)
  221.  
  222. 3.7    Decision to be taken at an international transit exchange
  223.  
  224.        The  decision  at  an  international  transit  exchange  depends  on   an
  225. assessment of switching and signalling information available after the transit CT has 
  226. selected an outgoing circuit. Information similar to that listed in 3.5 i) to vi) 
  227. above is of interest.
  228.  
  229. a)     When the first transit CT knows that an outgoing echo control device  has
  230. not yet been provided closer to the call source by a  signal  of  CCITT  Systems
  231. Nos. 6, 7 and R2, or by bilateral agreements for specific exceptions, the transit CT 
  232. should consider the outgoing circuit selected, the ultimate call destination and 
  233. such other information as indicated above. If a connection requiring echo control 
  234. may result, an outgoing echo control device should be enabled or inserted at the 
  235. first transit CT.
  236.  
  237. b)     When the transit CT concerned knows that an outgoing echo control  device
  238. is located closer to the call source, the question to be decided is the location 
  239. of the incoming echo control device. The incoming echo control device is located 
  240. at the transit CT only when a  location  nearer  to  the  called  party  is  not
  241. practicable. Specifically, an exception may result when the transit CT selects a short 
  242. terminal circuit equipped with CCITT Signalling Systems No. 4, 5 or R1.  In this 
  243. case, an incoming echo control device should be enabled or inserted at the transit 
  244. CT.
  245.  
  246. c)     It follows from the above that  in  every  case  where  an  international
  247. transit centre interconnects two circuits and knows that echo control device will be 
  248. provided at a preceding location and also at a more distant location, the transit 
  249. centre should disable or not insert its own echo  control  device.   (Full  echo
  250. control device is not covered in the control plan and should not be affected by the 
  251. procedures described in this section.)
  252.  
  253.  
  254.  
  255.  
  256.  
  257.  
  258.  
  259. d)     It is, of course, commonly the case that an outgoing echo control  device
  260. has not been introduced at the outgoing exchange because none is required.  When
  261. the transit exchange has reason to know  of  such  a  situation  it  should  not
  262. introduce an echo control device and should advise the subsequent exchange when possible 
  263. that an incoming echo control device is not required (or equivalently,  that  an
  264. outgoing echo control device has not been introduced).
  265.  
  266. e)     In the case of a routing where both an incoming and outgoing echo control 
  267. device has already been inserted at earlier points, the transit exchange  should
  268. advise the subsequent exchange, where possible, that an incoming half echo control 
  269. device is not required.
  270.  
  271. 3.8    Decision to be taken at the incoming international exchange
  272.  
  273.        Short circuits equipped with CCITT Systems No. 5, R1 and  No.  4  (unless
  274. bilateral agreements are reached), provide no signals at  the  incoming  CT  for
  275. selective use of echo control devices. As a result, in the absence of separate circuit 
  276. groups on the same route or other alternatives, the economic choice is  to  omit
  277. echo control devices. In the case of a call that has passed  through  a  transit
  278. exchange en route to the incoming exchange, the requirement for an incoming echo 
  279. control device should then be met at the preceding CT as covered in  3.7 b) above.
  280.  
  281.        With CCITT Systems Nos. 6, 7, R2 and  No.  4  (assuming  multilateral  or
  282. bilateral agreement) selective use of echo control devices on short terminal links is 
  283. a basic option. Therefore, the terminal CT acts in accordance with  the  control
  284. signal received. When an outgoing echo control device has  been  included  at  a
  285. preceding CT, the incoming CT should enable or insert an incoming echo control device.
  286.  
  287.        When no echo control device has yet appeared elsewhere in the connection, 
  288. none should be enabled or inserted at the incoming CT.
  289.  
  290. 3.9    Other considerations
  291.  
  292.        It is recognized that when echo control devices are inserted from  pools,
  293. there is a small probability that no echo control device will be available  when
  294. needed. In this case an (equipment) congestion signal should  be  given  to  the
  295. calling subscriber.
  296.  
  297.        Nothing in  this  Recommendation  should  be  construed  as  discouraging
  298. control measures which may supplement the plan described and lead to improved results 
  299. in specific situations. For example, regional procedures which introduce loss to 
  300. control echo may be arranged to satisfy both regional and international needs on a 
  301. selective basis. In addition for multiple ISC in one country  the  procedure  of
  302. Annex B may be applied. It is recognized that possibilities for echo control have 
  303. not been exhausted. If switching and signalling equipment have a changed role in 
  304. the application of future procedures, this Recommendation  will  be  subject  to
  305. revision.
  306.  
  307.  
  308.  
  309.  
  310.  
  311.  
  312.  
  313.  
  314.  
  315.  
  316.  
  317.  
  318.  
  319.  
  320.                                     Annex A
  321.                                         
  322.                            (to Recommendation Q.115)
  323.                                         
  324.                 Call processing logic - Echo suppressor control
  325.  
  326.  
  327.  
  328.  
  329.  
  330.  
  331.  
  332.  
  333.  
  334.  
  335.  
  336.  
  337.  
  338.  
  339.  
  340.  
  341.  
  342.  
  343.  
  344.  
  345.  
  346.                                 FIGURE B-1/Q.115
  347.                                         
  348.                    Echo control on multiple ISCs in a country
  349.  
  350.  
  351.                                    REFERENCES
  352.  
  353. [1]  CCITT Recommendation Echo suppressors suitable for circuits  having  either
  354.      short  or  long   propagation   times,   Volume   III   of   Orange   Book,
  355.      Recommendation G.161.
  356.  
  357. [2]  CCITT Recommendation Echo Suppressors, Volume III, Recommendation G.164.
  358.  
  359. [3]  CCITT Recommendation Echo Cancellers, Volume III, Recommendation G.165.
  360.  
  361. [4]  CCITT Recommendation Bearer services supported  by  an  ISDN,  Volume  III,
  362.      Recommendation I.231.
  363.