home *** CD-ROM | disk | FTP | other *** search
/ ftp.alaska-software.com / 2014.06.ftp.alaska-software.com.tar / ftp.alaska-software.com / updates / xbtw32e2.txt < prev    next >
Text File  |  1999-12-01  |  7KB  |  205 lines

  1. /*
  2.  * XBTW32E2.TXT 
  3.  *
  4.  * Service Level 2 notes for XbToolsIII Version 1.20.055
  5.  * for Window NT and Windows 95/98 (WIN32T)
  6.  *
  7.  * 
  8.  * Date: 11/01/1999
  9.  * 
  10.  */
  11.  
  12.  ___________
  13.  1. Overview
  14.  
  15.  This file contains important information about the installation procedure 
  16.  of this Service Level. 
  17.  
  18.  ___________________________________
  19.  2. Check your existing installation
  20.  
  21.      Please make sure you have the following products completely installed:
  22.  
  23.        - XbToolsIII 1.20.055
  24.  
  25.      If this is not the case, install XbToolsIII completely new from
  26.      your CD-ROM.
  27.  
  28.  2.1 Note for Xbase++ 1.20.178 Users
  29.  
  30.      This release of the XbToolsIII requires Alaska Xbase++ 1.30.212
  31.      (ServiceLevel 2) installed.
  32.  
  33.  
  34.  2.2 Note for Blinker 5.x Users 
  35.  
  36.      If you have copied the ..\LIB\OMF files into the ..\LIB directory,
  37.      you must copy the files from the directory ..\LIB\COFF back into 
  38.      ..\LIB before you proceed with the Service Level installation.
  39.  
  40.      Due to some support issues we do not recommend any more to copy
  41.      the OMF libraries into the ..\LIB directory when Blinker is used.
  42.      Instead, we recommend to change the LIB environment variable so that
  43.      it points to the appropriate directory:
  44.  
  45.         SET LIB=..\LIB\OMF
  46.  
  47.  
  48.  ________________________________
  49.  3. Copy the Service Level 2 file
  50.  
  51.     Download the file XBTW32E2.EXE to your computer.
  52.  
  53.     Now, copy the file XBTW32E2.EXE to the root path of your current 
  54.     XbToolsIII installation.
  55.  
  56.       [C:\ALASKA\XBTW32]copy \<your download-dir>\XBTW32E2.EXE  .\
  57.  
  58.     NOTE: If you have received the Service Level on CD-ROM, you must copy
  59.     the SL file to the harddisk of your computer. The ServiceLevel cannot 
  60.     be applied from CD-ROM!
  61.  
  62.  
  63.  ____________________ 
  64.  4. Apply the changes 
  65.  
  66.     The XBTW32E2.EXE is a self-extracting archive with an auto-start 
  67.     feature. It unpacks the necessary files and applies all 
  68.     changes automatically.
  69.  
  70.     To install the Service Level, enter on the command line:
  71.  
  72.       [C:\ALASKA\XBTW32]XBTW32E2.EXE
  73.  
  74.     Watch out for any error messages and/or check the SERVICE.LOG for
  75.     error messages.
  76.  
  77.     The patch works incremental. If you cancel the process or if an 
  78.     error occurs which you are able to resolve, you can restart the 
  79.     process at any time by entering on the command line:
  80.  
  81.       [C:\ALASKA\XBTW32]SERVICE.EXE
  82.       
  83.     The resulting XbToolsIII version number is 1.3.063. The version
  84.     number can be verified by activating the 'Help->About' dialog
  85.     of the online help or of the XbToolsIII Tester.
  86.  
  87.  
  88.  __________________
  89.  5. Deleting files
  90.  
  91.     If you don't have received the ServiceLevel on a CD-ROM,
  92.     we recommend to keep a backup copy of the files you have 
  93.     downloaded. 
  94.     To avoid any interference with upcoming service levels please
  95.     delete the files listed below from your installation directory.
  96.  
  97.     Here is the list of the files belonging to this ServiceLevel:
  98.  
  99.        XBTW32E2.EXE  - The self-extracting archive.
  100.        XBTW32E2.TXT  - This file.
  101.        XBTW32E2.RTP  - Patch data file
  102.        PATCHW32.DLL  - The patch utility.
  103.        SERVICE.EXE   - The patch utility GUI frontend.
  104.        SERVICE.LOG   - This file will be created if the patch 
  105.                        stopped due to errors.
  106.  
  107.  
  108.  _________________________________
  109.  6. How to contact Alaska Software
  110.  
  111.     Please report every information regarding this version to
  112.     the newsgroup
  113.   
  114.        alaska-software.news.Xbase++
  115.  
  116.     located on the news server news.alaska-software.com.
  117.  
  118.     To allow proper handling of your information, please include the 
  119.     product name including the version number you are talking about 
  120.     on the top of your message in a format like  "XbTools 1.30.063".
  121.  
  122.  
  123.  _______________________
  124.  7. List of closed PDR's
  125.  
  126.  This is a list of PDRs closed between version 1.20.055 and 1.30.063.
  127.  
  128.  
  129. PDR 209-61    InputMode() returns different value as CA Tools3
  130.               ( Windows 9x and Windows NT 4.0 )
  131.  
  132. PDR 209-64    GetClearA does return wrong value at initial state
  133.               ( Windows 9x and Windows NT 4.0 )
  134.  
  135. PDR 209-65    can't open COM higher then 9
  136.               ( Windows 9x and Windows NT 4.0 )
  137.  
  138. PDR 209-66    SpoolActive and SpoolAdd do not work together
  139.               ( Windows 9x and Windows NT 4.0 )
  140.  
  141. PDR 209-67    ALERT box is not visible when Wxxxx is used
  142.               ( Windows 9x and Windows NT 4.0 )
  143.  
  144. PDR 209-75    Internal data structures corrupted -> Function NumAt()
  145.               ( Windows 9x and Windows NT 4.0 )
  146.  
  147. PDR 209-77    Function AddMonth() returns empty date
  148.               ( Windows 9x and Windows NT 4.0 )
  149.  
  150. PDR 209-79    ShowTime doesn't work in Hybrid-Mode
  151.               ( Windows 9x and Windows NT 4.0 )
  152.  
  153. PDR 209-81    AddMonth() returns empty date
  154.               ( Windows 9x and Windows NT 4.0 )
  155.  
  156. PDR 209-82    DiskFree() and DiskTotal() return wrong values
  157.               ( Windows 9x and Windows NT 4.0 )
  158.  
  159. PDR 209-85    StrScreen() does not care about rows
  160.               ( Windows 9x and Windows NT 4.0 )
  161.  
  162. PDR 209-88    ScreenStr() works different; it does not mind the y value
  163.               ( Windows 9x and Windows NT 4.0 )
  164.  
  165. PDR 209-89    WOM() does return wrong values
  166.               ( Windows 9x and Windows NT 4.0 )
  167.  
  168. PDR 209-101   PosRepl() does not scan string beyond chr(0)
  169.               ( Windows 9x and Windows NT 4.0 )
  170.  
  171. PDR 209-102   Expand runs into "internal data structures corrupted"
  172.               ( Windows 9x and Windows NT 4.0 )
  173.  
  174. PDR 209-103   MaxRow()/ MaxCol() will not be replaced when linking XbTools
  175.               ( Windows 9x and Windows NT 4.0 )
  176.  
  177. PDR 209-108   SaveGets returns an empty Array
  178.               ( Windows 9x and Windows NT 4.0 )
  179.  
  180. PDR 209-125   FileSeek, FileDate, FileTime do not release file handle
  181.               ( Windows 9x and Windows NT 4.0 )
  182.  
  183. PDR 209-126   DirName() does not return a leading "\"
  184.               ( Windows 9x and Windows NT 4.0 )
  185.  
  186. PDR 209-127   AtNum() does not work when CHR(0) is searched for
  187.               ( Windows 9x and Windows NT 4.0 )
  188.  
  189. PDR 209-132   isDebug() always returns .F.
  190.               ( Windows 9x and Windows NT 4.0 )
  191.  
  192. PDR 209-136   FileSeek() quits app without any comment
  193.               ( Windows 9x and Windows NT 4.0 )
  194.  
  195. PDR 209-137   NNetSDate() has Y2K error
  196.               ( Windows 9x and Windows NT 4.0 )
  197.  
  198. PDR 209-138   WOPEN() doesn't stores the screen correctly
  199.               ( Windows 9x and Windows NT 4.0 )
  200.  
  201. PDR 209-140   DiskFree() and drives > 2GB aren't recognized correctly
  202.               ( Windows 95 )
  203.  
  204. Closed: 25
  205.