home *** CD-ROM | disk | FTP | other *** search
/ DP Tool Club 17 / CD_ASCQ_17_101194.iso / vrac / vds30p.zip / WHATSNEW.TXT < prev   
Text File  |  1994-08-18  |  2KB  |  56 lines

  1. What's new in VDS Pro 3.0N and 3.0P?
  2. ____________________________________
  3.  
  4. There is one significant modification to the operation of VDS Pro 3.0.
  5. The scanners in the VDS Pro package load the internal virus signatures
  6. from a file at run-time. This file is named VDSVSIGS.SIG and placed in the
  7. VDSPRO30 home directory. You can change the file name to something you wish
  8. to use as long as you update the entry for [INTSIGS] in the .INI files.
  9.  
  10. As usual, we have added identification for dozens of new viruses and
  11. corrected problems with recognition of some old viruses. We discovered a few
  12. minor bugs and fixed them.
  13.  
  14. Summary of Changes/Enhancements
  15. _______________________________
  16.  
  17. * Virus signatures are now kept in VDSVSIGS.SIG file. By replacing this
  18.   file, you can easily update the scanning capability of the programs
  19.   in the package. We will provide the updated .SIG file regularly.
  20.  
  21. * Fixed a bug that caused VDS not to function properly on some SCSI-drive
  22.   systems with an on-board BIOS and a known motherboard disk access point.
  23.   VDS would try to use the motherboard bios access and fail since hard disk
  24.   could not be accessed in this way. This problem surfaced when certain
  25.   old ASPI drivers were used.
  26.  
  27. * A few warning/error messages were displayed but never logged in the
  28.   VDS-STAT.LOG file. This has been corrected.
  29.  
  30. * In certain cases, VDS would log the time of operation as "PM" although
  31.   it was "AM" in actuality.
  32.  
  33. * A bug in the scanning routine caused VDS to miss some viruses although
  34.   the program had the correct signatures for them.
  35.  
  36. * Some faulty scan strings were replaced with correct ones.
  37.  
  38. * Certain command line options did not work properly. Fixed.
  39.  
  40. * We have added two new command line options to the INSTALL and VDS programs:
  41.      In INSTALL:
  42.            -D     Force VDS to generate debug report in C:\VDSDEBUG.LOG
  43.            -S     Force VDS to use SCSI-compatible code
  44.      In VDS:
  45.            -E     Use SCSI-compatible code
  46.            -Y     Generate debug report in C:\VDSDEBUG.LOG
  47.  
  48. * We have added a new command line option to VDSTSR:
  49.    VDSTSR  /D
  50.       -D  Diskswap, keep virus information on disk to reduce memory footprint.
  51.           Creates a file named C:\$VDSTSR$.SWP.
  52.  
  53. * If the DOS diskette was removed after booting off of it, then INSTALL