home *** CD-ROM | disk | FTP | other *** search
/ DP Tool Club 15 / CD_ASCQ_15_070894.iso / vrac / zhint594.zip / SYNC < prev    next >
Text File  |  1994-04-07  |  619b  |  17 lines

  1. 10-25-93
  2.  
  3.      We  haven't got the facilities to test Syncronous mode, Rockwell  does
  4. test  the  chipsets, and other users have it working too.  These  are  some
  5. hints to point you in the right direction.
  6.  
  7.      All  syncronous starts in Aysync mode. The three commands to set  Sync
  8. mode  are &Q1 &Q2 &Q3.(see your manual). Other commands which  affect  Sync
  9. mode are E &X &R &S which are explained the the chapter on Syncronous.
  10.  
  11.      Try factory default &D0 first with &C1. Then &C0 &D2 or &D3 or
  12. any combination.
  13.                                    Don Hinds - Zoom Tech
  14.  
  15. ##include=c:\text\signa.tif
  16.