| II07092 |
| COMMUNICATIONS MANAGER EXTENDED SERVICES 1.0 |
| |
| ES 1.0 Database Install Error 210 Description |
| and Resolution |
| |
|LAST UPDATE: 06/28/93 BY: GMB |
| |
+-------------------------------------------------------------+
|
| 1. 06/28/93 ES 1.0 Database Manager install error
| Description
|
| Problem: ES install of Database Manager fails on
| diskette 6 or 7
|
| The message from VIEWLOG says:
|
| 1) No C: SQLLIB DBDSGC.DAT - internal processing error 210
|
| Error codes: 02 07 24 2 DS 06
|
| insterr3 02 07 24 2 ds 06
|
| Calling Component==> Database Manager
| Failing Function===> Installation Services
| Error==============> 24 - Reserved
| Return Code========> 2
| Failing Module=====> MODS2.DS
| Error Number=======> 6
|
|
|
| 2) Error processing C: CONFIG.SYS
|
| Error codes: 02 14 02 02 DS 00
|
| insterr3 02 14 02 02 ds 00
|
| Calling Component==> Database Manager
| Failing Function===> Install Aid
| Error==============> ATF
| Return Code========> 2
| Failing Module=====> MODS2.DS
| Error Number=======> 0
|
| C: OS2 INSTALL DBLDGRPS.PIP
| C: SQLLIB DBDSGC.DAT
| C: OS2 INST
| database feature installation has failed due to
| a system error. APPC
|
|
| 2. 06/28/93 ES 1.0 Database Manager install error
| resolution:
|
| Action: Change the ESSTART.CMD on ES 1.0 diskette one
| and in the OS2 INSTALL subdirectory from %6
| to 200 correcting the 'INOS2REL' SET variable
| command statement. Don't forget to set the
| read/write protect tab to the write position
| on the ES 1.0 diskette before editing. If you
| do forget, you may get an error when trying to
| save the file (after setting the diskette tab)
| indicating that the diskette is full. If this
| happens, simply try the 'Save' function again.
| Save the file using file type 'Plain text'.
|
| REM SET INOS2REL=%6 <=== Change this line in the
| ESSTART.CMD. The ESSTART.CMD
| is found in two locations and
| must be changed in both.
|
| First, change the ESSTART.CMD
| file found in the subdirectory
| OS2 INSTALL on your harddisk.
|
| Second, change the ESSTART.CMD
| on diskette one of the Extended
| Services Install Package
| you are trying to install with.
|
| SET INOS2REL=200 <=== Line should be.
|