Error reading sector 14 of the new mirror drive.
Occurs on: SFT II and TTS.
Meaning: This error message indicates that the REMIRROR console
command was used to attempt to remirror a drive and
the file server could not correctly read sector 14 of
the new mirror drive. Sector 14 of the drive contains
the drive's mirror information. Although this is not a
fatal error, the remirror operation will be aborted.
Cause: The mirror drive or associated disk channel components
have failed.
Solution: Make sure that the drive is powered on. Attempt to
run the PREPARE utility and re-setup Hot Fix and
mirroring on the drive. If this fails, check all of
the components of the failed disk channel. Repair or
replace the drive, controller, or Disk Coprocessor
board that is defective and then attempt to remirror
the drive again with the PREPARE utility.
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.