Error reading disk redirection information on sector 14.  Run PREPARE.

     Occurs on:  SFT I.  This is an Abend error.

     Meaning:    This error indicates that the disk redirection
                 information on sector 14 of the currently mounting
                 drive could not be correctly read.

     Cause:      This could be caused by a failure in the drive, Disk
                 Coprocessor board (DCB), controller, or connecting
                 cables. It may also be caused by invalid information
                 written in sector 14 of the disk.

     Solution:   Ensure that the drive, the DCB, and the controller are
                 properly seated, connected, and powered on.  If nothing
                 wrong can be detected, run PREPARE on the drive and set
                 up Hot Fix again.  If this still does not fix the
                 problem, exchange the above mentioned components one by
                 one with known good ones until the problem component is
                 found.