Fatal File System Error: zero First or Current Cluster.
Occurs on: 68, 86, and 286. This is an Abend error.
Meaning: This error would be generated when a process in the operating
system attempts to extend an existing file and finds that the
first or the current cluster number is zero. A file's first
and current cluster numbers point to the physical area on the
disk that the file is located in. These numbers can never be
zero. This is a consistency check to ensure the integrity of
the file before the file is extended. The occurrence of this
error indicates that the file is potentially severely
corrupted.
Cause: This error could be caused by a memory failure in the file
server and could be attributable to either a hardware failure or
poor power line conditioning. This could also be caused by a
problem with the disk or related hardware.
Solution: Reboot the file server. Check the file server's memory and
power line conditioning. Check the disk and related hardware.
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.