[<<Previous Entry] [^^Up^^] [Next Entry>>] [Menu] [About The Guide]
ERROR READING NETWARE CONFIGURATION INFORMATION

Occurs on:  68, 86, and 286.  This is an Abend error.

Meaning:  This error will be displayed if the server cannot read from
          track 0 of the SYS: volume to get the disk configuration
          tables.  This is a fatal error.

Cause:  This error occurs if the disk is not configured correctly, if
        the disk related hardware is not working properly, or if a bad
        sector on track 0 of the disk is encountered.

Solution:  Use the SYSED utility to check the disk and verify the
           installation information.  If a disk error has been
           encountered, run the COMPSURF utility.  Repair or replace any
           disk related hardware that may not be working properly.
           Reinstall the operating system and/or restore the files from
           a backup if required.

This page created by ng2html v1.05, the Norton guide to HTML conversion utility. Written by Dave Pearson