Americel
832 Channel unit manufactured by Shintom
NAM Programming:
- Power on phone
- Lock phone using FUNC and 5
- FUNC # 626 # FUNC
- version and model will be displayed
- Press SEND to cycle through options, entering in new value if needed.
To access parameter by number, hit END (parameter number) SEND. Write to
phone when done with END FUNC END.
- Area code: 3 digits
- Phone Number: 7 digits
- System ID: 5 digits
- Access Overload Class: 2 digits
- Group ID: 2 digits
- Local Use: 1 digit
- MIN Opt.: 1 digit
- Lock Code: 3 digits (default is 123)
- Auto Lock: 1=enable 0=disable
- Call Restriction Code: 3 digits (default is 123)
- Call Counter Reset Code: 2 digits
- Hands-Free: 1=enable 0=disable
- Horn Alert: 1=enable 0=disable
- Horn Alert Auto (?)
- Standby Time: 0=2 hrs, 1=4 hrs, 2=8 hrs, 3=standby forever
- Cumulative Call Timer Reset: 2 digits (default is 12)