ALPINE 9510

                  NAM Type:  Fujitsu
              Manufacturer:  Fujitsu
                Programmer:  Curtis or Bytek
            ESN Prefix DEC:  150
                       HEX:  96
   ESN, S/N Match Required:  YES
      Programmable Handset:  No
        Available Channels:  666

       Phone Number Format:  XXX-XXX-XXXX
          Lock Code Format:  XXX

                MIN Option:  Enabled
          Repertory Option:  Enabled
          Handsfree Option:  Enabled or Disabled
          Local Use Option:  Enabled
     End-to-End Signalling:  Enabled
         Horn Alert Option:  Enabled
          System ID Format:  XXXXX
         Preferred Systems:  A or B
     Access Overload Class:  XX
           Group ID Format:  XX

    Initial Paging Channel:  333 or 334
             Station Class:  00

                Horn Alert:  F + #(Aux)
           New Unlock Code:  NAM
             System Select:  F + 1 + X
                               X=1  (A then B)
                               X=2  (B then A)
                               X=3  (A only)
                               X=4  (B only)
                               X=5  (Home)

                              ALPINE 9511

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN, S/N Match Required:  Yes
     Programmable Handset:  Yes
       Available Channels:  832

     Programming Sequence:  Power On
                            F + LOCK
                            POWER OFF
                            POWER ON
                            #626#7764726 (within 10 seconds)
                            HOLD (*) key until tone stops
                            Enter Data for each step then press STOR
                            Press SEND to write data

                         #Digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     08
   Initial Paging Channel:  3     333 or 334
    Access Overload Class:  2     XX
         Preferred System:  1     0 (B) or 1 (A)
          Group ID Format:  2     XX
                     Lock:  3or4  XXX or XXXX
               Call Timer:  1     4 (see i)
                Auto Lock:  1     1 (see ii)
         Call Restriction:  1     1 (see iii)

                                i. Call Timer - 1  Timer off
                                                2  6-seconds
                                                3  30-seconds
                                                4  60-seconds
  
                                ii. Auto Lock - 1  Manual Lock, No out
                                                2  Manual Lock, No calls
                                                3  Auto Lock, No out
                                                4  Auto Lock, No calls

                        iii. Call Restriction - 1  No Restriction
                                                2  No Memory Dialing
                                                3  No Long Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only
                                                   ALPINE 9511   NAMS 2,3,4

    Programming Sequences:  Power On
                            Unlock Power (if locked)
                            (F) (7) (NAM Number - 2, 3, or 4)
                            (F) (Lock)
                            Power Off
                            Power On
                            Follow Programming Code and Steps from Top Model

               Horn Alert:  F + # (Aux)
          New Unlock Code:  NAM
            System Select:  F + 1 + X
                              X=1  A then B
                              X=2  B then A
                              X=3  A only
                              X=4  B only
                              X=5  Home

                              ALPINE 9525 and 9530

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN, S/N Match Required:  Yes. Manufacturer Prefix + Last 4 or 5 digits
     Programmable Handset:  Yes
       Available Channels:  832

     Programming Sequence:  Power On
                            F + LOCK
                            Power Off
                            Power On
                            # + 626 + # + 7764726 (within 10 seconds)
                            Hold (*) key until tone stops
                            Enter data for each step then press STOR
                            Press SEND to write data

                        # of Digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     08 (Mobile) or 14 (Portable)
   Initial Paging Channel:  3     333 or 334
    Access Overload Class:  2     XX
         Preferred System:  1     1(A) or 0(B)
          Group ID Format:  2     XX
              Unlock Code:  3or4  XXX or XXXX
               Call Timer:  1     4 (i)
                Auto Lock:  1     1 (ii)
         Call Restriction:  1     1 (iii)
      System ID Inhibit #:  5     XXXXX
      System ID Inhibit #:  5     XXXXX
      System ID Inhibit #:  5     XXXXX

                         i. Call Timer Increment -  1 Timer Off
                                                    2  6-seconds
                                                    3  30-seconds
                                                    4  60-seconds

                        ii. Auto Lock -  1 Manual Lock, no out
                                         2  Manual Lock, No calls
                                         3  Auto Lock, No out
                                         4  Auto Lock, No calls

                       iii. Call Restriction -  1 No Restriction
                                                2  No Memory Dialing
                                                3  No Long-Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only

NAMS 2-4

     Programming Sequence:  Power On
                            Unlock Power (if locked)
                            F + 7 + NAM 2, 3 or 4
                            F + LOCK
                            Power Off
                            Power On
                            Follow Programming Code and steps from top example.

                              ALPINE 9550 Portable

                 NAM Type:  EEPROM
             Manufacturer:  Fujitsu
               Programmer:  Handset
           ESN Prefix DEC:  150
                      HEX:  96
  ESN/Serial Number Match:  Yes. Manufacturer prefix + last 4 or 5 digits
     Programmable Handset:  Yes
       Available Channels:  832
     Programming Sequence:  Power On
                            F + Lock
                            Power Off
                            Power On
                            # + 626 + # + 7764726 (within 3 seconds)
                            Hold (*) key until tone stops
                            Enter data for each step then press STOR
                            Press SEND to write data

                         # digits
         System ID Format:  5     XXXXX
         Local Use Option:  1     1
               MIN Option:  1     1
            Mobile Number:  10    XXX-XXX-XXXX
            Station Class:  2     14
   Initial Paging Channel:  4     0333 or 0334
    Access Overload Class:  2     XX
         Preferred System:  1     1(A) or 0(B)
          Group ID Format:  2     XX
              Unlock Code:  3or4  XXX or XXXX
               Call Timer:  1     4(i)
                Auto Lock:  1     1(ii)
         Call Restriction:  1     1(iii)

                         i. Call Timer Increment -  1 Timer Off
                                                    2  6-seconds
                                                    3  30-seconds
                                                    4  60-seconds

                        ii. Auto Lock -  1  Manual Lock, no out
                                         2  Manual Lock, No calls
                                         3  Auto Lock, No out
                                         4  Auto Lock, No calls

                       iii. Call Restriction -  1  No Restriction
                                                2  No Memory Dialing
                                                3  No Long-Distance
                                                4  Both 2 and 3
                                                5  Memory Calls only

     Programming Sequence:  Power On
                            Unlock Phone (if locked)
                            F + 7 + NAM 2, 3 or 4
                            F + LOCK
                            Power Off
                            Power On
                            Follow Programming Code and steps from above

          New Unlock Code:  NAM
            System Select:  FCN + 1 + X
                             X=1  AB
                             X=2  BA
                             X=3  A only
                             X=4  B only
                             X=5  Home

Curent status may be reviewed with RCL/ALT + FCN + 1



back to 
RadioPhone back to 
Cellular Programming mail 
DrWho

© 1994-1996 Copyright Sinister Networks. All rights reserved. May not be redistributed or modified without permission of Sinister Networks. Do not fold, spindle, or mutilate. Fnord.

Other names and marks used in here are the property of their respective owners, until and unless decided otherwise in a valid court of law. The absence of a service mark, trademark symbol or fnordmark in connection with the marks identifying products or services of other vendors does not indicate the absence of registration of those marks or devices. All marks identified herein are used or registered in the United States of America and may or may not be used and/or registered in other countries and planets.