INT 21 - European MSDOS 4.0 - HARD ERROR PROCESSING
        AH = 95h
        AL = new state
           00h enabled
           01h disabled, automatically fail hard errors
Return: AX = previous setting
Desc:   specify whether hard (critical) errors should automatically fail the
          system call or invoke an INT 24

See Also: 24