INT 7F - Alloy MW386 - ENABLE/DISABLE AUTOBAUD DETECT
        AH = 3Ch
        AL = new state
             00h disabled, 01h enabled
        DL = user number (FFh = caller)
        DH = machine number for user
Return: CF set if invalid user number
Note:   only available to supervisors

See Also: 7F3D