INT 6F - 10-NET - SPOOL/PRINT
AH = 0Eh
DS:DX -> spool/print record (see below)
Return: CF set on error
AX = error code (see also AH=00h)
FF17h device not mounted
FF18h already spooling to named device
CF clear if successful
Format of Spool/Print record:
Offset Size Description
00h WORD operation code
00h initiate spool
01h abort print
02h close spool
03h delete spool
04h print
05h get report info
06h set chat template
07h queue
08h return queue
09h queue non-spooled file for printing
02h 11 BYTEs file name in FCB format
---if operation code = 00h or 06h---
0Dh BYTE notification
bit 7: queue to top
bit 6: do ID page
bit 5: no form feed
bit 4: reserved
bit 3: explicity queuing only
bit 2: notify at print completion
bit 1: notify server operator/reply
bit 0: notify at print start
0Eh BYTE days to keep (FFh=forever)
0Fh BYTE bits 0,1: device (1=LPT1)
bits 4-7: remote drive to store spool file (1=A,...)
10h WORD length of following data area
12h N BYTEs up to 64 bytes of description
---if operation code = 03h---
0Dh 8 BYTEs user ID to associate with filename
---if operation code = 04h---
0Dh WORD block number
0Fh 8 BYTEs user ID to associate with filename
---if operation code = 05h---
0Dh BYTE RRN to start retrieve
0Eh BYTE bits 0,1: local print device (LPTx)
bit 3: if set, return entries for all users
0Fh WORD length of following area
11h N BYTEs up to 1500 bytes to receive $SCNTL records returned
---if operation code = 07h---
0Dh BYTE queue number
0Eh BYTE bits 0,1: local print device (LPTx)
0Fh WORD number of bytes of test print to be done
11h BYTE code: 01h print device
02h test print count
03h prn
---if operation code = 08h---
0Dh BYTE queue location or $SCNTL location to start access
returns next item for access:
00h-7Fh queued items
80h-FEh non-queued, non-printed items
FFh no more items
0Eh WORD unused
10h WORD length of following area
12h N BYTEs up to 64 bytes to receive $SCNTL records
---if operation code = 09h---
0Dh 3 BYTEs unused
10h N BYTEs path to non-spooled file to be queued for printing
Format of $SCNTL record:
Offset Size Description
00h 8 BYTEs user ID
08h 11 BYTEs filename in FCB format
13h 6 BYTEs node ID
19h 3 BYTEs creation date
1Ch BYTE flags
bit 7: queue to top
6: do ID page
5: no form feed at end
4: reserved
3: explicit queueing only
2: notify at completion
1: notify server operator/reply
0: notify at start
1Dh BYTE retention time in days
1Eh BYTE printing device (LPTx)
1Fh 3 BYTEs date last printed (0 = never)
22h BYTE device containing spoolfile
23h WORD bytes to print for test print
25h WORD block number to start print
27h BYTE reserved
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.