[<<Previous Entry] [^^Up^^] [Next Entry>>] [Menu] [About The Guide]
INT 60 u - HP 95LX System Manager - SET COMMUNICATIONS SETTINGS
        DI = 0E14h
        STACK:  2 WORDs unused dummies (for calls from high level languages)
                WORD    comm channel handle
                DWORD   pointer to comm settings (see below)
Return: ???
        STACK unchanged
SeeAlso: INT 60/DI=0E15h

Format of comm settings:
Offset  Size    Description
 00h    BYTE    dial type ('T' tone, 'P' pulse)
 01h    WORD    baud rate divisor (115200/baud_rate)
 03h    BYTE    parity (00h none, 08h odd, 18h even, 28h mark, 38h space)
 04h    BYTE    stop bits (00h one, 04h two)
 05h    BYTE    data bits - 5
 06h    BYTE    software handshake
                01h none, 02h XOFF/XON, 04h XOFF/any, 08h ENQ/ACK
 07h    BYTE    infrared (01h off, 02h on)
 08h    BYTE    duplex (01h half, 02h full)
 09h    BYTE    echo (01h echo, 02h no echo)

This page created by ng2html v1.05, the Norton guide to HTML conversion utility. Written by Dave Pearson