INT 21 - Novell NetWare - BINDERY SERVICES - WRITE PROPERTY VALUE
        AH = E3h subfn 3Eh
        DS:SI -> request buffer (see below)
        ES:DI -> reply buffer (see below)
Return: AL = status
            00h successful
            96h server out of memory
            E8h not item property
            ECh no such segment
            F0h wildcard not allowed
            F1h invalid bindery security level
            F8h not permitted to write property
            FBh no such property
            FCh no such object
            FEh server bindery locked
            FFh bindery failure
Note:   this function is supported by Advanced NetWare 1.0+ and Alloy NTNX
SeeAlso: AH=E3h/SF=3Ch,AH=E3h/SF=3Eh

Format of request buffer:
Offset  Size    Description
 00h    WORD    length of following data (max C5h)
 02h    BYTE    3Eh (subfunction "Write Property Value")
 03h    WORD    type of object (big-endian)
 05h    BYTE    length of object's name (01h-2Fh)
 06h  N BYTEs   object name
        BYTE    segment number (01h on first call, increment until done)
        BYTE    erase remaining segments (00h no, FFh yes)
        BYTE    length of property's name (01h-0Fh)
      N BYTEs   property name
    128 BYTEs   property value segment

Format of reply buffer:
Offset  Size    Description
 00h    WORD    (call) 0000h (no data returned)

See Also: 21E3