INT 21 - Novell NetWare - CONNECTION SERVICES - GET OBJECT CONNECTION NUMBERS
AH = E3h subfn 15h
DS:SI -> request buffer (see below)
ES:DI -> reply buffer (see below)
Return: AL = status
00h successful
Desc: this function retrieves a list indicating the connection numbers under
which a bindery object is logged into the default file server
Note: this function is supported by Advanced NetWare 1.0+ and Alloy NTNX
SeeAlso: AH=E3h/SF=16h
Format of request buffer:
Offset Size Description
00h WORD length of following data (max 33h)
02h BYTE 15h (subfunction "Get Object Connection Numbers")
03h WORD type of object (big-endian)
05h BYTE length of object's name (01h-2Fh)
06h N BYTEs object's name
Format of reply buffer:
Offset Size Description
00h WORD (call) length of following results buffer (max 65h)
02h BYTE number of connections
03h N BYTEs connection list