XCON: MTA Stops Unexpectedly When Message Volume Is Very High |
The information in this article applies to:
-
Microsoft Exchange Server, version 5.5
SYMPTOMS
When message volume is extremely high on a DEC Alpha computer, the message
transfer agent (MTA) may stop unexpectedly and an event similar to the
following may appear in the event log:
Source: MSExchangeMTA
Event: 9405
Type: Error
Category: Field Engineering
Description: An unexpected error has occurred which may cause the MTA
to terminate. Error: Access violation (0xc0000005) at Address 0x4aff38
reading from 0x0. [BASE XFER-IN 16] (16)
CAUSE
This problem can occur when a Microsoft Exchange function fails. Some
Microsoft Exchange functions are known to fail under stressful conditions
on DEC Alpha computers.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 5.5. This problem has been corrected in the latest U.S. Service
Pack for Microsoft Exchange Server version 5.5. For information on
obtaining the Service Pack, query on the following word in the Microsoft
Knowledge Base (without the spaces):
S E R V P A C K
Keywords : kbusage XCON kbbug5.50
Version : WINDOWS:5.5
Platform : WINDOWS
Issue type : kbbug