Server: NetWare 3.11 server NetWare 3.11 Server Driver Installation Notes for Intel's EtherExpress(TM) PRO/100 adapter ============================================ Location of driver: \NWSERVER\E100.LAN Location of NLMs: Novell's Automated Services Sample load commands ==================== LOAD C:\PATCHMAN LOAD C:\LSLENH LOAD C:\MSM31X LOAD C:\ETHERTSM LOAD C:\E100 SLOT=n FRAME=ETHERNET_802.3 BIND IPX TO E100 NET=xxxxxxxx General instructions ==================== 1. Install NetWare* 3.11 according to the NetWare 3.11 installation manual. 2. If you're using standard NetWare 3.11 (not SFT III), make sure your MONITOR.NLM is dated 10-26-92 (or later). This version of the NLM is on the Intel Configuration and Driver disk (in \NWSERVER\NLM311). Using an earlier version can cause server failure (ABENDs) when viewing statistics in monitor. 3. Load the NLMs: PATCHMAN.NLM (10-05-93 v2.30) LSLENH.NLM (10-05-93 v1.01) MSM31X.NLM (06-28-94 v2.31) ETHERTSM.NLM (06-28-94 v2.31) MONITOR.NLM (10-26-92 v1.75) Make sure you use these (or later) versions. Earlier versions may not work properly. If you can log in to the server, copy these files into the SYSTEM subdirectory. If you do this, you won't need to specify a path on the load line. If you copy it to another directory, make sure the LOAD statement includes the correct path. 4. Before starting the server, copy the E100.LAN driver from the \NWSERVER directory on the Configuration and Driver disk to the root directory of the hard drive of the server. If you can log in to the server, copy the driver to the SYSTEM subdirectory. If you do this, you won't need to specify a path on the load line. If you copy it to another directory, make sure the LOAD statement includes the correct path. 5. Modify the server's STARTUP.NCF to include: SET MAXIMUM PHYSICAL RECEIVE PACKET SIZE = 1536 (or larger) This preallocates server buffers. 6. Start the server. At the server console, issue the load and bind statement(s) in this order: LOAD C:\PATCHMAN LOAD C:\LSLENH LOAD C:\MSM31X LOAD C:\ETHERTSM LOAD C:\E100 SLOT=x FRAME=ETHERNET_802.3 BIND IPX TO E100 NET=xxxxxxxx Where: SLOT=x specifies the EISA slot number or PCI device number. Substitute x with the valid value for the adapter. This is optional for single adapter installations but required for multiple adapter installations. NET=xxxxxxxx is the unique network address for that LAN segment. If you have workstations using the 802.2 frame type, see the section later in this document about using multiple frame types on one adapter. 7. Add load and bind statements you need to the server's AUTOEXEC.NCF file so the EtherExpress(TM) PRO/100 adapter driver loads automatically each time the server starts. Hints and tips ============== Installing multiple adapters ---------------------------- - If you have multiple adapters in a single server, each adapter must have a different network number and SLOT number. Also, you may want to name each adapter. For example: LOAD C:\E100 SLOT=3 NAME=LAN_A BIND IPX TO LAN_A NET=222 LOAD C:\E100 SLOT=4 NAME=LAN_B BIND IPX TO LAN_B NET=333 - If you have problems loading the driver on multiple adapters and the initialization fails due to "Insufficient RCBs," increase the number of buffers allocated to the server. Add the following to STARTUP.NCF: SET MINIMUM PACKET RECEIVE BUFFERS = 100 (or larger) SET MAXIMUM PACKET RECEIVE BUFFERS = 500 (or larger) The MINIMUM value you specify must be at least 30 times the number of EtherExpress PRO/100 adapters in the computer. Recommended settings: 1-3 adapters: 100 4 adapters: 150 The MAXIMUM you can specify depends on the amount of memory in the server, but it must be greater than the MINIMUM. Installing one adapter with multiple frame types ------------------------------------------------ When binding multiple frame types to one adapter, enter a LOAD and BIND statement for each frame type. Each LOAD statement uses the same SLOT number, but each BIND statement needs a unique network number. You must also include a name on each load line to avoid being prompted for the board to bind IPX to. Example: LOAD C:\E100 SLOT=3 FRAME=ETHERNET_802.3 NAME=LAN8023 BIND IPX TO LAN8023 NET=77777 LOAD C:\E100 SLOT=3 FRAME=ETHERNET_802.2 NAME=LAN8022 BIND IPX TO LAN8022 NET=88888 Optional LOAD line parameters ----------------------------- SLOT: Specifies the slot number for EISA adapters. This is optional for single adapter installations but required for multiple adapters installations. For PCI adapters, SLOT is derived from DEVICE LOCATION and doesn't map to the physical location of the adapter. Currently, the PCI specification doesn't tell you how to determine which adapter corresponds to a device number. One way to do this is to load the driver from the command line. You'll be prompted with valid device numbers for the adapter. Select one of them. Syntax: SLOT=n (n = 1,2,3,4,...). SPEED: Specifies the speed the driver uses. If you don't use this parameter, the driver automatically detects the network speed. If no cable is attached, the driver defaults to 100 Mbps. If you use this parameter, the driver operates at the specified speed instead of detecting network speed. Syntax: SPEED=n (n = 10 or 100) Default: none, the adapter automatically senses speed THRESHOLD: Represents the threshold for transmits from extender SRAM FIFO. Syntax: THRESHOLD=n (n = number of 8 bytes). For example, 16 represents 16x8 (or 128 bytes). In this case, the LAN controller transmits after copying 128 bytes from the host memory. Default: 16 The maximum number that you can specify is 200 (200x8=1600 bytes). NODE: Specifies a local node address unique to each adapter. The first four digits of the address indicate who assigned the address when the driver loads. Syntax: NODE=00aa12345678 02aa => Locally administered address, 02 is set by MSM 00aa => Typical Intel address (default) BUSARCH: This parameter is required only if the system has both EISA and PCI slots and an EtherExpress PRO/100 adapter is in both types of slots. Syntax: BUSARCH=n (n = 2 for EISA, 1 for PCI) FRAME: Indicates one of four valid frame types the system is transmitting and receiving. Syntax: FRAME n n = Ethernet_802.2 Ethernet_802.3 Ethernet_II Ethernet_SNAP Default: Ethernet_802.3 * Third-party trademarks are the property of their respective owners.