Next | Prev | Up | Top | Contents | Index

sbe_mfr_override

Description

This parameter, when set to 1, overrides the default action of disabling single bit errors if the rate of single bit errors exceeds a predetermined limit. When set to 0, this feature is disabled.

Value

Default: 0 (0x0)

Range: 0 or 1

Notes

This parameter applies only to systems containing ECC memory (R8000-based systems such as CHALLENGE/Onyx)