Int 15 Fn 12  - Topview - Send Message - "write" - Write String To Window  (Cont.)

   F4h  position cursor to start of specific input field
        BYTE field number (1-N)
   F5h  change field table entry
        BYTE field number
        7-8 BYTEs field table entry (see opcode FFh below)
   F6h  set field type
        BYTE field number
        BYTE type
           00h inactive
           40h output field
           80h input field
           C0h deselected field
           C2h selected field
   F7h  "broadcast write"  write data to fields with program output bit
       set in field table entry, in field number order
        N BYTEs (total length of all program output fields)
   F8h  scroll field up a line
        BYTE field number
   F9h  scroll field down a line
        BYTE field number
   FAh  scroll field left
        BYTE field number
   FBh  scroll field right
        BYTE field number
   FCh  set field table header
        BYTE number of fields (must be <= existing number of fields)
        BYTE screen behavior bits
       bit 7  reserved
       bit 6  set if menu items may be selected via keyboard
       bit 5  set if left mouse button in "status" mode (press
           anywhere in window immediately returns control to app)
       bit 4  set if right mouse button in "status" mode
       bit 3  if set, select fields return contents or blanks rather
           than 'Y' or 'N'
       bit 2  if set, modified bits reset on return to application
       bits 0,1 = 00 no data returned on read of keyboard
              01 data returned as array of chars containing
               all fields packed together, with no field
               numbers
              10 data returned as numbered variable-length
               records for all fields
              11 data returned as numbered variable-length
               records for the fields which were modified
        BYTE current input field (updated by DESQview)
        BYTE current select field (updated by DESQview)
        BYTE attribute for select fields when they are pointed at
        BYTE attribute for select fields which have been selected
   FDh  reset modified bit for all fields
   FEh  reset selected and modified bits for all fields
   FFh  set up input fields
        6 BYTEs table header (see opcode FCh above)
        the field table entries, one for each field
        BYTE start row    \
        BYTE start column  \ if menu selection and start is to
        BYTE end row       / right or below end, select from kbd only
        BYTE end column   /
        BYTE field type
           bits 7,6 = 00 inactive (non-entry) field
                  01 echos keystrokes input to make menu selection
                  10 fill-in field
                  11 select field
           bit 5  field can be filled by broadcast write (F7h opcode)
           bit 4  reserved
           bit 3  reserved
           bit 2  reserved
           bit 1  set if field selected
           bit 0  set if field modified
        BYTE modifier
             if type is fill-in, then bit flags to determine behavior
             bit 7  if set, automatically enter CR when field full
             bit 6  move to next field when current field is full
             bit 5  if set, enter text from right end (for numbers)
             bit 4  if set, force input to uppercase
             bit 3  if set, clear old contents on first keystroke
             bit 2  if set, input returned when cursor moves out
                of modified field ("validate",API level 2.02+)
             bit 1  reserved
             bit 0  reserved
             if select field, first key to press to activate
             00h if have to point-&-click or is an extended-ASCII
                 keystroke (only if two-key menus enabled)
        BYTE (select field only) normal color of field
        BYTE second key for select field.  This byte is present iff
             two-letter menu entries selected with opcode E5h, and
             in that case is present regardless of field type

        Note: DESQview uses and updates the actual copy of the information
          which is contained in the stream.  Thus this info must remain
          intact until after the data entry is complete.

MODE 01h "QUERY STREAM" (valid only for those opcodes listed here)
   A0h return logical cursor row in next byte
   A1h return logical cursor column in next byte
   A2h return top row of scrolling region in next byte
   A3h return left column of scrolling region in next byte
   A4h return row of physical window origin in next byte
   A5h return column of physical window origin in next byte
   A6h return height of physcial window in next byte
   A7h return width of physical window in next byte
   A8h return row of viewport origin in next byte
   A9h return column of viewport origin in next byte
   AAh return height of virtual screen in next byte
   ABh return width of virtual screen in next byte
   AFh return current video mode in next byte
   C0h return current logical cursor position in next two bytes
   C1h return top left corner of scrolling region in next two bytes
   C2h return current window position in next two bytes
   C3h return current window size in next two bytes
   C4h return current viewport origin in next two bytes
   C5h return current virtual screen size in next two bytes
   D0h \ overwritten with D0h if frames may fall off screen edge
   D1h /              D1h if frames always displayed entirely
   D2h \ overwritten with D2h if DESQview controls color palette
   D3h /              D3h if application changes color palette
   D4h \ overwritten with D4h if window visible
   D5h /              D5h if window hidden
   D6h \ overwritten with D6h if window has frame
   D7h /              D7h if window unframed
   D8h \ overwritten with D8h if reading characters from window
   D9h /              D9h if reading attributes from window
   DAh \ overwritten with DAh if using logical attributes
   DBh /              DBh if using physical attributes
   DCh \ overwritten with DCh if TTY control char interpretation on
   DDh /              DDh if TTY control char interpretation off
   DEh \ overwritten with DEh if writing both characters and attributes
   DFh /              DFh if leaving attributes untouched
   E2h return current color in next byte
   ECh get logical attributes for window contents
       BYTE execute call if currently in specified video mode
       bit 7   monochrome
       bit 6   color text, EGA/VGA graphics
       bit 5   medium-resolution CGA graphics
       bit 4   high-resolution CGA graphics
       BYTE which attributes to get
       bit 7 unused???
       bits 4-6 first attribute to get - 1
       bits 0-3 # consecutive attributes
       N BYTEs buffer to hold attributes
   EDh get logical attributes for window frame
       BYTE execute call if currently in video mode (see opcode ECh)
       BYTE which attributes to get
       bit 7 unused???
       bits 4-6 first attribute to get - 1
       bits 0-3 # consecutive attributes
       N BYTEs buffer to hold attributes
   EEh get characters for window frame
       BYTE execute call if currently in video mode (see opcode ECh)
       BYTE which attributes to get
       bit 7 unused???
       bits 4-6 first char to get - 1
       bits 0-3 # consecutive chars
       N BYTEs buffer to hold chars
   EFh return first N characters of current window name
       BYTE    max length of returned name
       N BYTEs buffer to hold window name
   F3h return contents of specified field
       BYTE field number
       N BYTEs buffer to hold field contents (size exactly equal to field
           size)
   F5h get field table entry
       BYTE field number
       7-8 BYTEs buffer to hold field table entry

          Notes: DV < 2.26 always returns 7 bytes
             DV 2.26+ w/ APILEVEL < 2.26 returns 8 bytes iff field
           table is using 8-byte entries and eighth byte after
           F5h is E7h (NOP); otherwise, 7 bytes are returned
             DV 2.26+ w/ APILEVEL > 2.26 returns 7 or 8 bytes
           depending on the field table entry size
   F6h get type of a field
       BYTE field number
       BYTE type
   FCh get field table header
       6 BYTEs buffer to store header

MODE 10h "MANAGER STREAM" (valid only for opcodes listed here)
   00h allow window to be moved horizontally
   01h allow window to be moved vertically
   02h allow window to change width
   03h allow window to change height
   04h allow window to be scrolled horizontally
   05h allow window to be scrolled vertically
   06h allow "Close Window" menu selection for application
   07h allow "Hide Window" menu selection for application
   08h allow application to be suspended ("Rearrange/Freeze")
   0Eh allow "Scissors" menu
   10h allow DESQview main menu to be popped up
   11h allow "Switch Windows" menu
   12h allow "Open Window" menu
   13h allow "Quit" menu selection
   20h-33h opposite of 00h-13h, disallow specified action
   40h notify if horizontal position of window changes
   41h notify if vertical position of window changes
   42h notify if width of window changes
   43h notify if height of window changes
   44h notify if window scrolled horizontally
   45h notify if window scrolled vertically
   46h notify if window is closed--program has to clean up and exit itself
   47h notify if window is hidden
   48h notify if "?" on main menu selected
   49h notify if pointer message sent to window
   4Ah notify if window is placed in foreground
   4Bh notify if window is placed in background
   4Ch notify if video mode changes
   4Dh notify if "Scissors" menu "Cut" option selected
   4Eh notify if "Scissors" menu "Copy" option selected
   4Fh notify if "Scissors" menu "Paste" option selected
   50h notify if DESQview main menu about to pop up
   51h notify if DESQview main menu popped down
   60h-71h  opposite of 40h-51h: don't notify on specified event
   84h attach window to parent task's window (both move together)
   85h detach window from parent task's window (may move independently)
   86h disable background operation for application
   87h enable running in background
   88h set minimum size of physical window
       BYTE rows
       BYTE columns
   89h set maximum size of physical window
       BYTE rows
       BYTE cols
   8Ah set primary asynchronous notification routine
       DWORD address of routine, 0000h:0000h means none (see also below)
   8Bh set async notification parameter
       DWORD 32-bit value passed to 8Ah async routine in DS:SI
   ACh (DV2.2+) perform regular select field attribute processing
   ADh (DV2.2+) protect attributes in selected field from being lost
   AEh make window default notify window for owning app (API level 2.00+)
   AFh set selected field marker character
       BYTE character to display at left edge of selected fields
   BCh set standard field processing mode
   BDh set alternate field processing mode (enables cursor pad for menus)
   BEh disables changing reverse logical attributes with ECh opcode
   BFh enables changing reverse logical attributes with ECh opcode
   C0h make current window topmost in system
   C1h force current process into foreground
   C2h make current window topmost in process
   C3h position mouse pointer relative to origin of current field
       BYTE rows below upper left corner of field
       BYTE columns to right of upper left corner of field
   C4h position mouse pointer relative to origin of given field
       BYTE field number
       BYTE rows below upper left corner of field
       BYTE columns to right of upper left corner of field
   C5h orphan current window (also hides it)

       Note: must be last in stream; all subsequent commands ignored
   C6h show all windows for this process
   C7h hide all windows for this process
   C8h suspend process and hide all its windows