[<<Previous Entry]
[^^Up^^]
[Next Entry>>]
[Menu]
[About The Guide]
Int 60 - Excelan LAN Workplace For DOS 3.5 - API [N]
ES:BX -> request packet
Return: request packet updated
Notes: this interrupt is also supported by Beame&Whiteside's BWLWP35 shim,
which was used in creating this description
the installation check consists of testing for the WORD 4142h ('AB')
immediately preceding the interrupt handler
BUG: because BWLWP35 range-checks only the low byte of the function number,
and has a fencepost error even in that test, functions 000Bh and
XX01h-XX0Bh (XX nonzero) branch to random locations
See Also: INT 2F/AX=7A40h
Format of request packet:
Offset Size Description
00h 12 BYTEs ???
0Ch WORD (return) error code (see below)
0Eh DWORD -> FAR function for ???
12h WORD function number
0001h ???
0002h NOP
0003h NOP
0004h NOP
0005h ???
0006h get ??? record
0007h NOP
0008h reset ???
0009h NOP
000Ah set ???
???
---function 01h---
20h BYTE (call) subfunction (32h-3Bh)
3Bh non-blocking I/O request (will be tested every clock tick)
21h BYTE (return) error code
00h successful
09h invalid connection number
2Ah bad connection type
45h ???
---function 01h, subfunction 32h---
3Ah WORD (call) connection type (01h stream, 02h datagram)
---function 01h, subfunction 34h---
26h WORD (call) ???
28h WORD (call) ???
2Ah WORD (call) ???
---function 01h, subfunction 35h---
1Ah WORD (call) connection number???
26h WORD (return) ???
---function 01h, subfunction 36h---
1Ah WORD (call) connection number???
38h WORD ???
---function 01h, subfunction 37h---
24h WORD (return) ???
26h WORD (return) ???
---function 01h, subfunction 38h---
1Ah WORD (call) connection number???
---function 01h, subfunction 3Ah---
22h WORD (call) ???
667Eh ???
667Fh ???
24h BYTE (call 667Eh) ???
24h WORD (return 667Fh) ???
---function 01h, subfunction 3Bh---
0Eh DWORD (call) -> function to invoke for I/O or 0000h:0000h
function called with AX = 0000h
STACK: DWORD -> request packet
WORD 0000h
should return STACK unchanged
1Ah WORD (call) connection number???
21h BYTE (return) set to 01h when I/O becomes possible
22h BYTE (call) direction (00h write, 01h read)
34h DWORD (return) -> next pending request packet
---function 05h---
1Eh WORD (call) ???
20h WORD (call) ???
34h DWORD (call) -> ???
---function 06h---
16h DWORD (call) -> buffer for ??? record (see below)
1Ah WORD (call) number of bytes to copy
22h WORD (return) number of bytes transferred
---function 08h---
14h WORD (return) ??? (0001h)
---function 0Ah---
16h DWORD (call) -> WORD ???
1Ch WORD (call) must be 000Ah for BWLWP35
Values for error code:
0000h successful
002Dh invalid function
0050h ???
Format of ??? record:
Offset Size Description
00h WORD offset of ???
02h 4 BYTEs ???
06h DWORD IP address (big-endian)
0Ah 6 BYTEs physical address (big-endian)
???
This page created by ng2html v1.05, the Norton guide to HTML conversion utility.
Written by Dave Pearson