Int 21 Fn E3 - Novell Netware - Bindery Services - Verify Bindery Object [N]
AH = E3h subfn 3Fh
DS:SI -> request buffer (see below)
ES:DI -> reply buffer (see below)
Return: AL = status (see below)
Note: this function is supported by Advanced NetWare 1.0+ and Alloy NTNX
See Also: AH=E3h/SF=40h
Values for status:
00h successful
96h server out of memory
F0h wildcard not allowed
FBh no such property
FCh no such object
FEh server bindery locked
FFh bindery failure: no such object, bad password, no password for object,
or invalid old password
Format of request buffer:
Offset Size Description
00h WORD length of following data (max 133h)
02h BYTE 3Fh (subfunction "Verify Bindery Object Password")
03h WORD (big-endian) type of object
05h BYTE length of object's name (01h-2Fh)
06h N BYTEs object name
BYTE length of password (00h-7Fh)
N BYTEs password
Format of reply buffer:
Offset Size Description
00h WORD (call) 0000h (no data returned)