Int 21 Fn 3F - Trusted Access - Nb.sys - Get State [y]
AH = 3Fh
BX = file handle for device "$$NB$$NB"
CX = 0002h (size of state)
DS:DX -> buffer for state record
Return: CF clear if successful
AX = number of bytes actually read (0 if at EOF before call)
CF set on error
AX = error code (05h,06h) (see AH=59h)
Program: Trusted Access is a security and access-control package by Lassen
Software, Inc.; NB.SYS is a device driver to prevent the user from
terminating CONFIG.SYS or AUTOEXEC.BAT with Ctrl-Break
See Also: AH=40h"NB.SYS",AX=4101h
Format of state record:
Offset Size Description
00h BYTE 00h off, 01h on
01h BYTE keys being disabled
bit 0: Ctrl-Break
bit 1: SysRq
bit 2: Ctrl and Alt
bit 3: Ctrl-Alt-Del
bit 7: all keys (overrides other bits)