Invalid mirror definition table. Run PREPARE.
Occurs on: SFT I, SFT II, TTS. This is an Abend error.
Meaning: This error indicates that the mirror definition table
has been corrupted. The mirror definition table
contains the drive mirror assignments. This error is
displayed if there are more mirrored drives in the
table than the number of installed drives on the
system. Although SFT I does not support disk
mirroring, it still uses the mirror definition table.
Cause: The most probable cause of this error is that the
virror definition table stored on the disk has been
overwritten with invalid information.
Solution: The PREPARE utility should be run to re-setup the disk
mirror assignments and rebuild the mirror definition
table. Although SFT NetWare Level I does not support
disk mirroring, PREPARE should be run anyway to repair
the mirror definition table.