DISK NOT UPGRADED TO ADVANCED NETWARE
Occurs on: 68, 86 and 286. This is an Abend error.
Cause: This error occurs when a file server is attempting to mount a
drive utilizing Advanced NetWare and the drive was originally
installed with a version of NetWare prior to Advanced NetWare
1.0. This error could also occur if track 0 of the disk has
been damaged or overwritten.
Solution: If you do not want to upgrade the disk to Advanced NetWare,
you will need to boot the file server with an earlier version
of NetWare. If you want to upgrade the file server to
Advanced NetWare, you will need to run the UPGRADE utility
found on the INSTALL diskette of Advanced NetWare. This
utility should be run only once for each disk that is to be
upgraded.
If the disk has been previously operating under Advanced
NetWare, then track 0 has probably been damaged or overwritten.
In this case, you will have to run COMPSURF on the disk. All
files on the disk will have to be restored from a backup after
running COMPSURF.